AmeriVent® Pipe and
Fittings feature rugged, double-wall construction of corrosion-resistant
galvanized steel and aluminum, Snap-Lock coupling ends and are lightweight
for easy one-man installation.
NOTE: AmeriVent® Snap-Lock joints overlap. To calculate height,
deduct 1" for each joint.
Available in the following:
Sizes 3" through 8"
Lengths 6", 12", 18", 24", 3', 4' and 5' (except
8")
Sizes 9" through 30"
Lengths 12", 18", 24", 3'
Adjustable Lengths
Adjustable Lengths telescope
onto standard AmeriVent pipe sections for adjustments from 3"
to 16".
Available in the following:
Sizes 3" through 8"
Lengths 12" that adjust from 3" - 10"
Sizes 9" through 30"
Lengths 18" that adjust from 3" - 16"
Adjustable 90°
"L"
Adjustable "L's"
are constructed from four sections for smoother bends and less resistance.
It adjusts from 0° to 90° easily to clear rafters or ceiling
joists.
Standard Tees feature
identical trunk and branch diameters. For smaller diameter applications,
use a reducing tee. For larger diameter applications, use an increaser
with this standard tee.
Available in the following:
Sizes 3" through 30"
Reducing Tee
Reducing Tees feature
a smaller branch diameter than trunk size. This allows for convenient
connections of furnaces and water heaters to a common vent.
Available in the following:
Sizes 4" through 6"
Standard Wyes
Standard Wyes feature
identical branch, truck and base diameters.
Available in the following:
Sizes 4"
Reduction Wyes
Reduction Wyes feature
smaller branch and/or base diameters than the trunk. This allows for
convenient double wall connections to furnace or water heater in one
common connector.
Available in the following:
Sizes 4" through 6"
Universal Adaptors
- Male
Universal Adaptors offer
secure, listed connections between AmeriVent Type B Gas Vents and
gas vents from other manufacturers installed below.
Available in the following:
Sizes 3" through 6"
Universal Adaptors
- Female
Universal Adaptors offer
secure, listed connections between AmeriVent Type B Gas Vents and
gas vents from other manufacturers installed above.
Available in the following:
Sizes 3" through 6"
VPH Vent Pipe Hanger
VPH hangers provide
1½" spacing and are orderd in the same size as Type B Gas
Vent. Hangers provide support for offsets and horizontal runs of AmeriVent.
Available in the following:
Sizes 3" through 7"
SBA Vent Pipe Hanger
SBA Hangers provide 2"
spacing and should be ordered smaller than Type B Gas Vent.
Available in the following:
Sizes 8" through 10"
Tee Cap
Tee Caps provide a closure
for the branch or truck of a tee.
Available in the following:
Sizes 3" through 30"
Draft Hood Connector
Draft Hood Connectors
connect Type B Gas Vents directly to appliance draft hoods. The flexible
inlet can be shaped to fit oval draft hood outlets.
Available in the following:
Sizes 3" through 12"
Increaser
Increasers are used to
increase vent size.
Available in the following:
Sizes 3" through 30"
Gripper Support and
Firestop
Installs quickly, saving time
and money. Gripper fingers can hold anywhere on the pipe.
Supports up to 30 feet of pipe. Clearance ring assures that the
required 1" clearance to combustibles is maintained. UL-listed as a
support and firestop.
Available in the following:
Support and Firestop
Sizes 3" through 6"
Bucket and Support
Use Bucket Supports for
starting a vent at ceiling level. Supports provide proper clearance,
automatic positioning and fit between 16" O.C. joints.
Available in the following:
Bucket and Support
Sizes 3" through 8"
Bucket only
Sizes 9" through 30"
Firestop Support
Firestop Supports are
designed to support Type B Gas Vents starting at appliance level while
also serving as a firestop.
Support Brackets can be purchased separately but are included with
the Support as well.
Available in the following:
Sizes 3" through 8"
Support Plate
Designed to provide strength
and durability, Support Plates also double as firestops.
Available in the following:
Sizes 9" through 30"
Support Plate
This Support Plate supports
a 3" - 6" Tee and is used as a base for Type B Gas Vents.
Available in the following:
One size only
Vent Collar
Vent collars provide cover
for rough wall openings. Hole size is designed to accomodate AmeriVent®
Type B Gas Vent.
Available in the following:
Sizes 3" through 12"
Storm Collar - Fixed
Storm Collars serve as
counter flashings and should be used with mastic to seal the collar
to the pipe.
Available in the following:
Sizes 3" through 6"
Storm Collar - Adjustable
Storm Collars serve as
counter flashings and should be used with mastic to seal the collar
to the pipe.
Available in the following:
Sizes 7" through 30"
Wall Thimble
Wall Thimbles adjust for
various wall thicknesses from 4" to 6" and provide proper
clearance for venting from combustibles.
Available in the following:
Sizes 3" through 12"
Flashing - Standard
Standard flashings fit
various pitch roofs from flat to 5/12. Its double seamed construction
protects from water leakage.
Available in the following:
Sizes 3" through 30"
6" skirt
Flashing - Tall Cone
Tall cone flashings fit
various pitch roofs from flat to 1/12. Use tall cone flashings on
flat roofs in snow-packed areas to reduce chances of leakage.
Available in the following:
Sizes 3" through 30"
Riser 12"
Flashing - Steep
Pitch
Steep pitch flashings
its 6/12 to 12/12 pitch roofs and its double seemed construction protects
from water leakage.